Your healthcare provider will guide you through the process to ensure that you restore as much mobility as possible to your knee. This website uses cookies to improve your experience while you navigate through the website. Recovery can be long, and side effects are common. In addition, the anterior F.A.S.T. visualization, and allow for percutaneous screw placement., The anatomic shape of the plate allows screw trajectories to The anatomically contoured plate is designed to replicate the patient's specific scapular anatomy, thereby resulting in a more secure reconstruction of severely displaced fractures. Treatment depends on how the kneecap breaks. maximize screw position and limit intra-articular and neurovascular compromise. If you think you can, but it is still painful, its probably best not to try until you have been diagnosed. 1. The patella has a thick layer of cartilage, which can be injured in the break. Resource Type: If you choose to logout it will log you out from all the applications. A patella fracture is usually caused by a direct blow to your kneecap, such as in a fall, from a sports injury or from a car accident. Screw is also available to compress the plate to the bone. any locking hole, giving the surgeon intraoperative flexibility. A recent study evaluated construct failure after an open reduction and plate fixation and reported a construct failure rate of 6.9% of which 1.9% were related to broken plates. design of this screw allows the head to sit level with the plate These Quadrupled semitendinosus-gracilis autograft fixation in the femoral tunnel: a comparison between a metal and a bioabsorbable interference screw Plate breakage is one form of construct failure after a clavicle fracture treated with an open reduction and plate fixation. Patented SmartLock polyaxial locking technology 1. could be slightly varied (outside of the targeting guide) with either Mechanical testing is not necessarily indicative of clinical performance., Quantifying Your Patient Recovery with ZBEdges Persona IQ and the mymobility Care Management Platform, AAOS Las Vegas 03.08.23, Dealers Choice: ORIF vs. Total Hip Replacement AAOS Las Vegas 03.08.23, Zimmer Biomet Announces Fourth Quarter and Full-Year 2022 Financial Results, Zimmer Biomet Announces Webcast and Conference Call of Fourth Quarter 2022 Financial Results, Hindfoot: Calcaneus Fracture, Medial Calcaneal Slide, Small Standard, 2-Hole 3). It can be used to repair a high ankle sprain, which damages the soft tissue structures between the tibia and fibula and causes these bones to separate. If you cant, that will likely necessitate surgical intervention. Distal femur fractures are traumatic injuries involving the region extending from the distal metaphyseal-diaphyseal junction to the articular surface of the femoral condyles. Talonavicular joint arthrodesis with VariAx plate. extended 2-Hole, large extended 2-Hole, and large extended 3-Hole The aim of the PSCG is to dene the PSCG is anatomical. The patella SuturePlate (Fa. requirements present in the trabecular anatomy of the calcaneus. Depending on the force applied, it may create a hairline crack, break into two pieces or it may break into many small pieces. The demonstration is performed by Dr. Donald Bohay and John Anderson of Grand Rapids, MI. accurate screw insertion, radiolucent for enhanced x-ray A patella fracture is a break in your kneecap, the bone that covers your knee joint. To prevent disruption of the medially based vascular supply to the patella,34 a lateral parapatellar arthrotomy is then performed, fracture hematoma is evacuated, and the knee joint is irrigated. This site is intended for healthcare professionals. Arthrex is the first company to obtain FDA clearance for plating in patella fracture indications. Designed with the surgeon in mind, the plates have many features to help create a more reproducible procedure: The locking straight plates include a slide hole, which allows slight movement across the fracture line to facilitate the best plate placement. It covers the incision, the desired outcome, the osteotomy and fixation. The Medial Anti-Glide Plate is designed to address vertical shear fractures of the medial malleolus. Abstract and Figures Transverse patella fractures with loss of knee extensor mechanism function are a common orthopaedic injury requiring operative fixation. Wild et al. Medial column arthrodesis with VariAx plate. Broken pieces may move out of line or break through the skin. Youll be allowed to bear as much weight as you feel comfortable. the calcaneus anatomy as needed. Steinmetz S, Brgger A, Chauveau J, et al. that require plate strength and the ability to insert screws around Seemlessly connect, products, services and technologies to elevate Patella Fracture Repair with Patella SuturePlate Arthrex Europe 539 subscribers Subscribe 24 Save 6.3K views 5 years ago .more .more Notice Age-restricted video (based on Community. Apple Watch and iPhone are trademarks of Apple, Inc., registered in The quadriceps and patellar tendon attach to your patella, which normally allows you to flex and extend your knee. Pain is usually moderate and manageable with over-the-counter medications. 24515 Open treatment of humeral shaft fracture with plate/screws, with or without cerclage 24516 Treatment of humeral shaft fracture, with insertion of intramedullary implant, with or without cerclage and/or locking screws 24545 Open treatment of humeral supracondylar or transcondylar fracture, includes internal fixation, Designed with the surgeon in mind, the plates have many features to help create a more reproducible procedure: The locking straight plates include a slide hole, which allows slight movement across the fracture line to facilitate the best plate placement. Etes-vous un professionnel de sant pratiquant en France? This video demonstrates a medial column fusion. In addition to the new OrthoLine fracture plates, the fracture management system includes a variety of screw options, including fully threaded headless compression screws, partially threaded screws, cannulated lag screws, low-profile screws, and QuickFix cannulated screws. This may lead to arthritis of the knee joint. All content herein is protected by copyright, trademarks and other [13] showed that surgical experience may improve the surgeon's competency in prevention of lateral hinge fractures, highlighting the need to be . warnings, precautions, potential adverse effects and patient correspond to the complicated anatomy of the calcaneus. Minimally-Invasive and Mesh Calcaneus Plating System The demonstration is performed by Dr. Donald Bohay and John Anderson of Grand Rapids, MI. The 70-plate, state-of-the-art fracture line includes sizes 1.6 mm, 1.6 mm broad, 2.0 mm, 2.4 mm, 3.0 mm, and 3.5 mm for straight and T-style plates and 3.5 mm broad straight plates for both feline and canine patients. With a multipartite patella, the volume of the true patella plus that of the smaller ossification centers is greater than that expected of a normal patella. Principles. The low-profile plates are available in a wide range that Incision is made, distal radius is identified, manipulated into place, and two pins across both fragments to maintain alignment. Permanent loss of motion in your knee, especially in its ability to bend and extend. The optimal fixation of operatively treated patella fractures continues to evolve (See Fig. address a variety of calcaneus fractures, while meeting the stress experience.Mymobilitydelivers continuous data and addition to these locking screw designs, a cobalt chrome3.5 mm Functional outcomes of revision osteosynthesis after failure of surgical treatment of patellar fractures. P atella fracture is a common injury seen in all age groups and accounts for approximately 1% of all fractures. Arthritis can cause pain and stiffness. Wright PB, Kosmopoulos V, Cot RE, Tayag TJ, Nana AD. Certain products may not be approved for sale in all countries. Patella SuturePlate System Offers a unique and ultimate rigid method for the accurate reduction of patella fractures. Low Profile VA Locking Screw, 3.0 x 10 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 12 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 14 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 16 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 18 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 20 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 22 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 24 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 26 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 28 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 30 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 32 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 34 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 36 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 38 mm, Titanium, Low Profile VA Locking Screw, 3.0 x 40 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 40 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 42 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 44 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 46 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 48 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 50 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 52 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 54 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 56 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 58 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 60 mm, Titanium, QuickFix Screw, Titanium, Cannulated, Short Thread, Cancellous 4.0 x 28 mm, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 30 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 32 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 34 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 36 mm, Titanium, QuickFix Screw, Cannulated, Short Thread, Cancellous 4.0 x 38 mm, Titanium, Handle, Quick Coupling Ratcheting, Cannulated, Bone Reduction Forceps, Curved, Pointed, qty 2, Drive Shaft, Cannulated, QC, T15 Hexalobe, Screw Holding Sleeve for 2.7, 3.5 and 4 mm Screws, Surgical Technique Guides | English | 03/03/2023 | LT1-000206-en-US B, Surgical Technique Animations | 02:13 | English | 01/13/2023 | AN1-000279-en-US B, Surgical Technique Videos | 04:22 | English | 02/04/2022 | VID1-003070-en-US A, Brochures | English | 01/28/2021 | LB1-000259-en-US A, 04:22 | English | 02/04/2022 | VID1-003070-en-US A, 02:13 | English | 01/13/2023 | AN1-000279-en-US B, English | 03/03/2023 | LT1-000206-en-US B, English | 01/28/2021 | LB1-000259-en-US A. It includes 4.0 mm blunttipped cannulated screws that, when used in conjunction with FiberTape as an anterior tension band, creates a. We strive to alleviate pain and improve the quality of life for people around the world. Any compromise of the joint surface is likely to lead to degenerative joint disease. trajectory of the screw hole may not be ideal. A patellar fracture is a break in your kneecap. The locking patella plate (Arthrex, Munich, Germany) is available in two different specifications: the Arrowplate and the Starplate ( Fig. Necessary cookies are absolutely essential for the website to function properly. intellectual property rights, as applicable, owned by or licensed to 2023 Arthrex, Inc. All rights reserved. Licensed from Prof. D. Wolter, Hamburg, GermanyStryker Corporation or its divisions or other corporate affiliated entities own, use or have applied for the following trademarks or service marks: Anchorage, Stryker, VariAx. Functional outcomes of revision osteosynthesis after failure of surgical treatment of patellar fractures. 2). 3.5 mm Multi-Directional Locking Screws or 3.5 mm Low Profile simple fall onto the knee or motor vehicle injuries) or indirectly following a forceful contraction of the quadriceps with the knee in a flexed position [ 2 ]. 1 It is generally accepted that instability of the syndesmosis after stable fracture fixation requires reduction and fixation in order to optimise the outcome. The 4.0 mm blunt-tipped cannulated screws were designed specifically for patella fractures. Retinacular Closure. With a patellar fracture, the volume of the fractured components is equivalent to that of a normal patella. Place pedicle screws in the vertebrae caudal and cephalad to the involved vertebra in preparation for posterior instrumentation (Fig. Patella Fracture. Tibial Plateau Fracture Surgery is required when the bone breaks into two or more fragments and surgery is normally needed. The patella is a vital part of the biomechanical excursion of the extensor apparatus of the knee [].A fractured patella can disrupt the extensor mechanism in combination with incongruent posterior articular surface and thus cause long-term complications, e.g., discomfort due to femoropatellar osteoarthritis [2, 3].The established treatment options depend on the underlying fracture pattern. calcaneus plate portfolio therefore providing comprehensive plating At first, you wont be allowed to flex your knee, but flexion will be allowed slowly, over time. Patellar stability and osteosynthesis rates have been shown to improve significantly with locked plates. Arthrex 2 years 10 months Shoulder Consultant Arthrex Jul 2018 - Feb 2020 1 year 8 months. This category only includes cookies that ensures basic functionalities and security features of the website. Naples, FL; 2013. of complex patellar fractures. The Mesh plates are a hybrid of the MIS and A.L.P.S. The A.L.P.S. Medial Border Plate The primary packaging has been selected to not include latex in any form. Current accepted surgical options. The Patella Fracture System includes everything needed to repair transverse patella fractures. intra-articular screw placement. This plate functions similarly to a one-third tubular plate but is more contoured and includes a distal cluster of 2.7 mm hexalobe screws to capture fragments in cases with distal comminution. These authors . Policy. This set includes 4.0 mm blunt-tip cannulated lag screws, which feature smooth tips to help avoid cutting suture, and a specially designed 5-in needle for easily passing suture through the screws to create tension-band fixation. Straight Plate Broad, Titanium, 1.6 mm, 5 Hole, Straight Plate Broad, Titanium, 1.6 mm, 6 Hole, Straight Plate Broad, Titanium, 1.6 mm, 7 Hole, Straight Plate Broad, Titanium, 1.6 mm, 8 Hole, Straight Plate Broad, Titanium, 1.6 mm, 9 Hole, Straight Plate Broad, Titanium, 1.6 mm, 10 Hole, T-Plate, Titanium, 1.6 mm, 2-Hole / 3-Hole, T-Plate Broad, Titanium, 1.6 mm, 2-Hole / 3-Hole, T-Plate Broad, Titanium, 1.6 mm, 3-Hole / 4-Hole, Low-Profile Cortical Screw, Titanium, 1.6 X 6 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 7 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 8 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 9 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 10 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 11 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 12 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 13 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 14 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 16 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 18 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 20 mm, Low-Profile VAL Screw, Titanium, 1.6 X 6 mm, Low-Profile VAL Screw, Titanium, 1.6 X 7 mm, Low-Profile VAL Screw, Titanium, 1.6 X 8 mm, Low-Profile VAL Screw, Titanium, 1.6 X 9 mm, Low-Profile VAL Screw, Titanium, 1.6 X 10 mm, Low-Profile VAL Screw, Titanium, 1.6 X 11 mm, Low-Profile VAL Screw, Titanium, 1.6 X 12 mm, Low-Profile VAL Screw, Titanium, 1.6 X 13 mm, Low-Profile VAL Screw, Titanium, 1.6 X 14 mm, Low-Profile VAL Screw, Titanium, 1.6 X 16 mm, Low-Profile VAL Screw, Titanium, 1.6 X 18 mm, Low-Profile VAL Screw, Titanium, 1.6 X 20 mm, Straight Plate, Titanium, 2.0 mm, 10 Hole, Straight Plate, Titanium, 2.0 mm, 11 Hole, Straight Plate, Titanium, 2.0 mm, 12 Hole, Straight Plate, Titanium, 2.0 mm, 13 Hole, Straight Plate, Titanium, 2.0 mm, 14 Hole, Straight Plate, Titanium, 2.0 mm, 15 Hole, T-Plate, Titanium, 2.0 mm, 2-Hole / 4-Hole, T-Plate, Titanium, 2.0 mm, 3-Hole / 4-Hole, Low-Profile VAL Screw, Titanium, 2.0 X 6 mm, Low-Profile VAL Screw, Titanium, 2.0 X 7 mm, Low-Profile VAL Screw, Titanium, 2.0 X 8 mm, Low-Profile VAL Screw, Titanium, 2.0 X 9 mm, Low-Profile VAL Screw, Titanium, 2.0 X 10 mm, Low-Profile VAL Screw, Titanium, 2.0 X 11 mm, Low-Profile VAL Screw, Titanium, 2.0 X 12 mm, Low-Profile VAL Screw, Titanium, 2.0 X 13 mm, Low-Profile VAL Screw, Titanium, 2.0 X 14 mm, Low-Profile VAL Screw, Titanium, 2.0 X 16 mm, Low-Profile VAL Screw, Titanium, 2.0 X 18 mm, Low-Profile VAL Screw, Titanium, 2.0 X 20 mm, Low-Profile VAL Screw, Titanium, 2.0 X 22 mm, Low-Profile VAL Screw, Titanium, 2.0 X 24 mm, Low-Profile VAL Screw, Titanium, 2.0 X 26 mm, Low-Profile VAL Screw, Titanium, 2.0 X 28 mm, Low-Profile VAL Screw, Titanium, 2.0 X 30 mm, Straight Plate, Titanium, 2.4 mm, 10 Hole, Straight Plate, Titanium, 2.4 mm, 11 Hole, Straight Plate, Titanium, 2.4 mm, 12 Hole, Straight Plate, Titanium, 2.4 mm, 13 Hole, Straight Plate, Titanium, 2.4 mm, 14 Hole, Straight Plate, Titanium, 2.4 mm, 15 Hole, T-Plate, Titanium, 2.4 mm, 2-Hole / 4-Hole, T-Plate, Titanium, 2.4 mm, 3-Hole / 4-Hole, Low-Profile VAL Screw, Titanium, 2.4 X 8 mm, Low-Profile VAL Screw, Titanium, 2.4 X 9 mm, Low-Profile VAL Screw, Titanium, 2.4 x10 mm, Low-Profile VAL Screw, Titanium, 2.4 X 11 mm, Low-Profile VAL Screw, Titanium, 2.4 X 12 mm, Low-Profile VAL Screw, Titanium, 2.4 X 13 mm, Low-Profile VAL Screw, Titanium, 2.4 X 14 mm, Low-Profile VAL Screw, Titanium, 2.4 X 16 mm,Low-Profile VAL Screw, Titanium, 2.4 X 16 mm, Low-Profile VAL Screw, Titanium, 2.4 X 18 mm, Low-Profile VAL Screw, Titanium, 2.4 X 20 mm, Low-Profile VAL Screw, Titanium, 2.4 X 22 mm, Low-Profile VAL Screw, Titanium, 2.4 X 24 mm, Low-Profile VAL Screw, Titanium, 2.4 X 26 mm, Low-Profile VAL Screw, Titanium, 2.4 X 28 mm, Low-Profile VAL Screw, Titanium, 2.4 X 30 mm, Straight Plate, Titanium, 3.0 mm, 10 Hole, Straight Plate, Titanium, 3.0 mm, 11 Hole, Straight Plate, Titanium, 3.0 mm, 12 Hole, Straight Plate, Titanium, 3.0 mm, 13 Hole, Straight Plate, Titanium, 3.0 mm, 14 Hole, Straight Plate, Titanium, 3.0 mm, 15 Hole, T-Plate, Titanium, 3.0 mm, 2-Hole / 4-Hole, T-Plate, Titanium, 3.0 mm, 3-Hole / 4-Hole, Low-Profile Cortical Screw, Titanium, 3.0 X 8 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 10 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 12 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 14 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 16 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 18 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 20 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 22 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 24 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 26 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 28 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 30 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 32 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 34 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 36 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 38 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 40 mm, Low-Profile Locking Screw, Titanium, 3.0 X 8 mm, Low-Profile Locking Screw, Titanium, 3.0 X 10 mm, Low-Profile Locking Screw, Titanium, 3.0 X 12 mm, Low-Profile Locking Screw, Titanium, 3.0 X 14 mm, Low-Profile Locking Screw, Titanium, 3.0 X 16 mm, Low-Profile Locking Screw, Titanium, 3.0 X 18 mm, Low-Profile Locking Screw, Titanium, 3.0 X 20 mm, Low-Profile Locking Screw, Titanium, 3.0 X 22 mm, Low-Profile Locking Screw, Titanium, 3.0 X 24 mm, Low-Profile Locking Screw, Titanium, 3.0 X 26 mm, Low-Profile Locking Screw, Titanium, 3.0 X 28 mm, Low-Profile Locking Screw, Titanium, 3.0 X 30 mm, Low-Profile Locking Screw, Titanium, 3.0 X 32 mm, Low-Profile Locking Screw, Titanium, 3.0 X 34 mm, Low-Profile Locking Screw, Titanium, 3.0 X 36 mm, Low-Profile Locking Screw, Titanium, 3.0 X 38 mm, Low-Profile Locking Screw, Titanium, 3.0 X 40 mm, Low-Profile VAL Screw, Titanium, 3.0 X 8 mm, Low-Profile VAL Screw, Titanium, 3.0 X 10 mm, Low-Profile VAL Screw, Titanium, 3.0 X 12 mm, Low-Profile VAL Screw, Titanium, 3.0 X 14 mm, Low-Profile VAL Screw, Titanium, 3.0 X 16 mm, Low-Profile VAL Screw, Titanium, 3.0 X 18 mm,Low-Profile VAL Screw, Titanium, 3.0 X 18 mm, Low-Profile VAL Screw, Titanium, 3.0 X 20 mm, Low-Profile VAL Screw, Titanium, 3.0 X 22 mm, Low-Profile VAL Screw, Titanium, 3.0 X 24 mm, Low-Profile VAL Screw, Titanium, 3.0 X 26 mm, Low-Profile VAL Screw, Titanium, 3.0 X 28 mm, Low-Profile VAL Screw, Titanium, 3.0 X 30 mm,Low-Profile VAL Screw, Titanium, 3.0 X 30 mm, Low-Profile VAL Screw, Titanium, 3.0 X 32 mm, Low-Profile VAL Screw, Titanium, 3.0 X 34 mm, Low-Profile VAL Screw, Titanium, 3.0 X 36 mm, Low-Profile VAL Screw, Titanium, 3.0 X 38 mm, Low-Profile VAL Screw, Titanium, 3.0 X 40 mm, Low-Profile Locking Screw, SS, 4.0 X 18 mm, Low-Profile Locking Screw, SS, 4.0 X 20 mm, Low-Profile Locking Screw, SS, 4.0 X 22 mm, Low-Profile Locking Screw, SS, 4.0 X 24 mm, Low-Profile Locking Screw, SS, 4.0 X 26 mm, Low-Profile Locking Screw, SS, 4.0 X 28 mm, Low-Profile Locking Screw, SS, 4.0 X 30 mm, Low-Profile Locking Screw, SS, 4.0 X 32 mm, Low-Profile Locking Screw, SS, 4.0 X 34 mm, Low-Profile Locking Screw, SS, 4.0 X 36 mm, Low-Profile Locking Screw, SS, 4.0 X 38 mm, Low-Profile Locking Screw, SS, 4.0 X 40 mm, Low-Profile Locking Screw, SS, 4.0 X 42 mm, Low-Profile Locking Screw, SS, 4.0 X 44 mm, Low-Profile Locking Screw, SS, 4.0 X 46 mm, Low-Profile Locking Screw, SS, 4.0 X 48 mm, Low-Profile Locking Screw, SS, 4.0 X 50 mm, Low-Profile Locking Screw, SS, 4.0 X 52 mm, Low-Profile Locking Screw, SS, 4.0 X 54 mm, Low-Profile Locking Screw, SS, 4.0 X 56 mm, Low-Profile Locking Screw, SS, 4.0 X 58 mm, Low-Profile Locking Screw, SS 4.0 X 60 mm, Low-Profile Locking Screw, SS 4.0 X 65 mm, Guidewire with Trocar Tip, 1.1 mm X 150 mm, Depth Device, 2.7/ 3.5/ 4.0 mm, Low Profile, Vet, Screw Holding Forceps, Self-Retaining, Vet, General OrthoLine Sterilization Case Insert, 1.6 mm and Broad 1.6 mm OrthoLine Plates and Screws, 3.5 mm and Broad 3.5 mm/4.0 mm OrthoLine Plates and Screws, OrthoLine Disposables and Limited Reusables, OrthoLine Distal Humeral Fracture System: Canine Elbow Procedure Demonstration, OrthoLine Distal Humeral Fracture System: Sawbone Application on a Canine Elbow Procedure Demonstration, OrthoLine Fracture Management System: Sawbone Application on a Canine Tibia, OrthoLine Distal Humeral Fracture System, OrthoLine Small Animal Fracture Straight Plate, OrthoLine Fracture Management System: Design Features, OrthoLine Distal Humeral Fracture Management System Weight Reference Chart, OrthoLine Fracture Management System: Weight Reference Chart, Inventory Control Form: 3.5 mm Fracture Plates and Screws, Inventory Control Form: 3.0 mm Fracture Plates and Screws, Inventory Control Form: 1.6 mm Fracture Plates and Screws, OrthoLine Universal Plating System: Clinical Case Series II, OrthoLine Fracture Management System: Clinical Case Series, OrthoLine Fracture Management System: Biomechanics, Standing Room Only: Veterinary WebInHourOrthoLine System Overview, Cortical/locking/variable-angle locking screws, Indicated for sizes from small cats to large dogs, Presenter: Sean M. Murphy, DVM, DACVS, Presenter: Mark Rochat, DVM, MS, DACVS, Presenter: Sarah Malek, DVM, PhD, DACVS-SA, Presenter: Susan Schaefer, DVM, MS, DACVS. If you have any further questions in this regard please contact your Customer Service Representative and they will assist you as promptly as possible. Ligament Augmentation Repair - Product and Technique Highlights - LS1-0408-EN. Multi-Directional Locking Screw is available when the fixed These anatomically contoured plates are not Screw options and instruments to address a If you suffer from chronic stiffness or weakness in your joint, you may want to continue wearing a knee brace for support. In addition, FiberTape. On the other hand, Lee et al. Stryker Corporation or its divisions or other corporate affiliated entities own, use or have applied for the following trademarks or service marks: Anchorage, Stryker, VariAx. Open the catalog to page 5 options for calcaneus fracture management.. This video demonstrates a talonavicular fusion. Some patella fractures are simple, but this small bone is also capable of breaking into many pieces. features two distinct and anatomically contoured plate designs that Fit for patients Fit for procedures Fit for you Fit for the future Contact Related categories Orthopaedics the plate will alter targeting guide alignment. Patella SuturePlate II Adequate reduction of provide both strength to the inner area of the plate, and the perimeter of the plate.. The cartilage can be injured with this type of fracture, which can lead to post-traumatic arthritis. counseling information, see the package insert or contact your local Both plates are anatomically shaped and provide unidirectional angular-stability as well as suture holes for the fixation of soft tissue to the plate. To address various types of fractures, the Patella SuturePlate II system offers three types of plates in different sizes. for intra-articular fractures of the calcaneus, whereas the small They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. The fracture pattern can be transverse, vertical or stellate [ 3 ]. Get to know Zimmer Biomets leadership team. The A.L.P.S. The healing process for a patella fracture can vary, depending on the severity of your break and whether you had surgery or not. the calcaneus will allow good plate/bone apposition. 3-Hole Extended, These two new plate designs expand upon Zimmer Biomets Seven new indication specific plates. This site is for visitors from the United States. 2.7 mm, 3.5 mm and4.0 mm locking screws that can be inserted into The system is made of titanium and offers three plating options, each in various sizes. They will check for open wounds and for signs of hemarthrosis blood from the broken bone pieces collecting in your joint, which can cause excessive swelling. Follow the guidance of your healthcare provider and avoid too much activity too soon. Dr. Adam Schiff demonstrates a Fifth Metatarsal procedure using VariAx fracture plates. The distinct andsimple-to-use carbon fiber targeting guides (small Certain products may not be approved for sale in all countries. 1370 Creekside Boulevard Naples, FL 34108 United States Phone: +1-800-934-4404 Fax: +1-800-643-9310 Latex Information Arthrex, Inc. products are designed without any latex components or packaging. Are you a medical professional residing in France? Distribution to any other recipient is prohibited., For product information, including indications, contraindications, The report includes a detailed description and tips of the surgical technique. You also have the option to opt-out of these cookies. Fixation. Patented SmartLock polyaxial locking technology, Locking screws can be angled 15 for a total range of 30. We do not endorse non-Cleveland Clinic products or services. The Arthrex SuturePlate II system can be used to address various types of patella fractures. They represent only 1% of all fractures. Plates are compatible with the TightRope syndesmosis. Suture holes can be used for soft-tissue attachment or ligament bracing.